Industrial Centrifugal Fan

CF Small Low Noise Centrifugal Fan

CF Model Highlights:

 

  • CF(A) type low noise multi-wing centrifugal fan is made to match the developing demand of purifying industry, ecology, and noise decreasing.
  • All impeller is well balanced to make sure the fan works stably with low noise, hiCgh air volume, small vibration and long life.It’s widely used for kitchen exhausting, oil fume extraction or ventilation of Canteen,Hotel, Restaurant
  • It’s also suitable to be used together with grain machinery, chemical machinery and plastic machinery.
  • The air delivered should be non hypergol and harmless gas without stickum, and temperature≤80℃, dust and PM≤150mg/m³.

 

CF Model Features:

: Material Properties

: During the design process, we use the design way of multi-objective optimization for noise, efficiency to get the best performance integrally. It’s with good aerodynamic performance.

: It can be used on many factorys which has some paper need to be make up together. This blower is design with 8 sizes like No. 1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5. There’s dextrorotation and levorotation for impeller rotating direction

: Fan Structure

: This blower is composed by Inlet, Impeller, Casing, and Motor.

Impeller: Made of high-quality steel plate, Riveted with 40-80 thin arc impeller, hub and hub cover. It’s balanced well statically and dynamically which gets it a good aerodynamic performance low noise, and stable operation.
Casing: The whole casing is welded with high-quality steel plate. Spiral tongue is with new type of noise elimination structure to get lower noise.
Inlet: Weld convergent clipper-built normal steel plate with front cover together.

: Installation

:: Install the fan according to the pictures, make sure that the shell is clean inside out, remain the balance of the fan while installing it, the contact surface between fan and the base, the connections between inlet pipe and the fan should be fixed with each other naturally, don’t force them, it’s forbade to transfer the pipe’s weight on the fan, and ensure the balance of the fan.

: Operating

:  After the installation and the inspection, we will have a test run, and it should be under no-load condition, by close all air inlet valve, then turn into full-load accordingly by the operating situation, by open all air inlet valve, the test run for new fan and the fan after repairing can’t be lessor than 2 hours.

: Maintenance

: The maintenance can only be done when the fan is stopped to ensure the safety. After the maintenance please remember to have a test run first before operating it. And also remember to clan the dust, dirt and other impurities regularly. If the fan is using in kitchen or spraying occasion, please clean the impeller every 60 days, otherwise it will cause the overloading of the fan by damage the motor and reduce the air volume.

 

Model Power
(KW)
Voltage
(V)
RPM
(r/min)
Volume(m³/h) Pressure(Pa )
1.5A 0.37 220 2800 830~1080 790~748
0.37 380 2800 830~1080 790~748
2A 1.1 220 2800 1248~2258 1150~839
1.1 380 2800 1248~2258 1150~839
0.37 220 1400 650~1125 248~210
0.37 380 1400 650~1125 248~210
2.5A 2.2 220 2800 748~2617 1542~1296
2.2 380 2800 748~2617 1542~1296
0.75 220 1400 1400~2300 377~320
0.75 380 1400 1400~2300 377~320
0.55 220 1400 1500~2200 367~312
0.55 380 1400 1500~2200 367~312
3A 1.5 220 1400 2033~3500 800~715
1.5 380 1400 2033~3500 800~715
1.1 220 1400 1960~3300 810~750
1.1 380 1400 1960~3300 810~750
0.75 380 910 1300~2252 350~315
3.5A 3 220 1420 3233~5000 1050~800
3 380 1420 3233~5000 1050~800
2.2 220 1420 3000~4800 1032~900
2.2 380 1420 3000~4800 1032~900
1.1 380 910 2300~3150 460~385
4A 4 380 1450 4000~6500 1300~980
1.1 380 910 2500~4200 600~520
4.5A 3 380 960 4500~6500 764~630

Quick Inquiry